PORT ORDINACE NO. 034/2004 - Ravenna 19-July-2004


Ravenna Port Ordinance for new navigating details

 

Starting July 19th 2004 in accordance to Harbourmaster's ordinance no. 034/2004 went in force om today following new maximum  limits for LOA/BEAM/DRAFT to be applied :

LOA 261 - BEAM 35  maximum draft : 28ft - 8,53 mt   in high tide condition otherwise in normal tide condition maximum allowed draft is 27ft - 8,23 mt

LOA 261 - BEAM 33 and below   draft : 28'06" - 8,68 mt in high tide condition otherwise in normal tide condition maximum allowed darft is 27ft - 8,23 mt

LOA 246 and below - BEAM 35 maximum draft : 28'06" - 8,68 mt in high tide condition otherwise in normal tide condition maximum allowed draft is 28 ft - 8,53 mt

LOA 246 - BEAM 33 and below draft : 29'06" - 8,99 mt in high tide condition otherwise in normal tide condition maximum allowed darft is 27ft - 8,23 mt

LOA 236 and below - BEAM 35 maximum draft : 30ft  - 9,14 mt in high tide condition otherwise in normal tide condition maximum allowed darft is 29ft - 8,84

LOA 236 - BEAM 33 and below   drafft : 30ft6" - 9,29 mt in high tide condition otherwise in normal tide condition maximum allowed darft is 29ft - 8,84

LOA 226and below - BEAM 36 maximum draft : 30ft6" - 9,29 mt in high tide condition otherwise in normal tide condition maximum allowed darft is 30ft - 9,14 mt

LOA 226 - BEAM 33 maximum draft : 31ft - 9,45 mt in high tide condition otherwise in normal tide condition maximum allowed darft is 30ft6" - 9,29 mt

LOA 226 - BEAM 31 and below   maximum draft : 31ft  - 9,45 mt also same draft in normal tide condition

LOA 210 and below - BEAM 28 and below maximum draft : 31ft6" - 9,60 mt in high tide condition otherwise in normal tide condition maximum allowed draft is 31ft - 9,45 mt

CANALE BAIONA ( PIR JETTIES )

 

L.O.A.

BEAM

Draft in Feet  (*)

in good weather condition

Draft in metres (*)

in good weather condition

180

27

30

9,14

185 (*)

33

28 (*)

8,53 (*)

 

NIGHT TIME NAVIGATION

 

From breakwater to San Vitale Basin  ( Non tanker vessel ):

 

ENTERING (*) /SAILING

L.O.A

Beam

Draft  in feet

Draft in metres

 

 

Tide

Tide

 

 

High  tide

Normal

Compulsory no. of tug

High tide

Normal

Compulsory no. of tug

210

30

29

28

Nil

8,84

8,53

Nil

Fitted with  Radar with minimum range 0.25 miles and P.P.I. of almost 16”

236

33 and below

26

25

2

7,92

7,62

2

226

33 and below

27

26

2

8,23

7,92

2

Fitted by bow thrusters /azipot and radar minimum range 0,25 miles and P.P.I. of almost 16”

236

33 and below

27

26

2

8,23

7,92

2

226

33 and below

28

27

2

8,53

8,23

2

 

 

 

 

 

 

 

 

For vessel fitted by two propellers and back rudder drafts are increased of one foot

on the maximum above indicated in high tide condition

 

(*) During adverse weather condition for visibility, wind, currents or tide the maximum

     allowed dimensional limits are reduced (in entrance ) by 10 metres for the length

     1 metre for beam and 30 cm ( 1 foot ) on draft in spite of the sailing vessel

(*) Vessels fitted by two propellers and no. 2 manoeuvring bow thrusters propellers

      in fine weather conditions are dispensed of tugs

SHIFTING INSIDE THE PORT ALLOWED WITH MAXIMUM DRAFT 28FT

 

From breakwater to San Vitale Basin  (Tanker vessel including chemical and LPG/C):

 

ENTERING  /SAILING

L.O.A.

Beam

Draft in feet

Draft in metres

165

28

26’6”

8,07

185 (*)

28 (*)

26’6”

8,07

(*) If not carrying or if empty ex liquid goods with flash point equal or < 65°  or goods which could develop toxic noxious vapours

 

CANALE BAIONA ( PIR JETTIES )

IN ENTRANCE

L.O.A.

Beam

Draft in feet

Draft in metres

180

27

28

8,53

ON SAILING

With bow toward shore

150

27

28

8,53

With bow toward Entrance

180

27

28

8,53

Tanker vessel with GRT over than 1600 which carries liquid goods in bulk of Cat. A ( with flash point below 21° Cent degrees or B below 65° Cent degrees ) or goods which could develop toxic noxious vapours minimum one tug is compulsory

 If the L.O.A. is over tann120 metres the minimum tugs to be used must be not less tan 2

 

For more details and before any fixing You are kindly requested to contact this office